PPE & Safety

Electric-Shock-Resistant Shoes: When Are They Required?

Most safety-shoe orders in India include a line for “electrical shoes” or “electric shock resistant shoes”, and most of those lines stop there. No rating, no standard, no description of the work. Yet “electrical” covers four very different kinds of footwear, from shoes that bleed off static to boots built for live-line work, and the wrong kind can be useless, or dangerous, in the wrong place.

So when do your people actually need electric-shock-resistant shoes? The answer depends on the work, the voltage and the atmosphere. Here is how to decide: what the rating means, which jobs call for it, where it should never be worn, and how to check a pair before it reaches your stores.

The rule in one sentence: Issue electric-shock-resistant (EH-rated) shoes to anyone who could accidentally contact, or stand near, energised conductors and equipment, and upgrade to class-rated insulating footwear (EN 50321) for deliberate live work. Never issue them in explosive atmospheres or static-sensitive areas, where antistatic or conductive footwear is required instead.

What “Electric-Shock-Resistant” Actually Means

An electric-shock-resistant shoe has a sole and construction designed to resist the flow of current from the foot to the ground. If a worker accidentally touches a live part, the shoe reduces the chance that current will find a path through the body and out through the feet.

The rating most often quoted comes from the American standard ASTM F2413. Footwear marked EH (electrical hazard) must withstand 18,000 V at 60 Hz for one minute, with no more than 1.0 mA of leakage current, under dry conditions. To pass, the shoe is built without conductive paths: no metal nails through the sole, an insulating rubber or polyurethane outsole, and usually a non-metallic shank. Many designs use composite toe caps and non-metal eyelets as well.

The test itself is simple to picture. The inside of the shoe is filled with small steel balls, which form one electrode, and the shoe stands on a metal plate, which forms the other. The test voltage is applied between the two, and the leakage current through the sole is measured. Any breakdown, or leakage above the limit, is a fail.

Two words in the definition matter more than the numbers.

“Secondary”. EH footwear is designed as secondary protection against accidental contact. It is not a licence to work on live equipment, and it doesn’t replace isolation, insulated tools, rated gloves or insulating mats.

“Dry”. The rating is tested on clean, dry footwear. Water, sweat, mud, worn soles and embedded metal all reduce its protection.

That also explains the “18 kV” printed on many listings. It is the test voltage for a secondary protection rating, not a working voltage. A shoe marked “18 kV” is not approved for work on 11 kV equipment, or on any live equipment.

Four Kinds of “Electrical” Footwear

Four families of footwear deal with electricity, and they are not interchangeable. Two keep current out; two deliberately let static charge drain away.

Footwear type What it does Main standard and marking Where it belongs
Electrically insulating footwear Primary insulation for live working, in classes by voltage EN 50321-1: Classes 00 to 4, double-triangle symbol Live working on LV, MV and HV systems, as part of a full live-working kit
Electric-shock-resistant (EH) footwear Secondary protection against accidental contact ASTM F2413 “EH” Electricians, maintenance technicians, substation and solar crews
Antistatic footwear Drains static at a controlled rate to prevent sparks ISO 20345 / IS 15298 symbol “A” (included in S1 and higher classes) Refineries, fuel stations, paint shops, solvent stores, pharma and chemical plants
Conductive and ESD footwear Drains static quickly ISO 20345 symbol “C”; IEC 61340 for ESD Explosives handling, electronics assembly

Insulating footwear to EN 50321-1 is the heavyweight of the group. It covers shoes, ankle boots, half-knee and knee boots, and overboots for installations up to 36,000 V AC, in six classes:

EN 50321-1 class Maximum nominal voltage (AC) AC proof-test voltage
00 500 V 2.5 kV
0 1,000 V 5 kV
1 7,500 V 10 kV
2 17,000 V 20 kV
3 26,500 V 30 kV
4 36,000 V 40 kV

The lower classes also carry DC limits: 750 V for Class 00 and 1,500 V for Class 0.

These products carry the same double-triangle symbol as live-working gloves, a class marking, and a space to record the date of first use and each periodic inspection. EN 50321-1 explicitly excludes shock-resistant, antistatic and conductive footwear, and BSI notes that a separate European part for electric-shock-resistant footwear is in development.

Antistatic footwear sits at the other end of the scale. Its resistance must lie between 100 kΩ and 1,000 MΩ, which is low enough to drain static safely but nowhere near high enough to insulate against mains voltage. IS 15298 (Part 2) states plainly that antistatic footwear does not protect against electric shock from AC or DC voltages.

When Are Electric-Shock-Resistant Shoes Required?

What Indian rules say

India’s electrical safety rules are set by the Central Electricity Authority. Regulation 21 of the CEA (Measures relating to Safety and Electric Supply) Regulations, 2023, which deals with handling electric supply lines and apparatus, includes rubber safety footwear rated for the working voltage in its list of equipment to be used, together with rubber gloves, helmets, safety belts and earthing devices. Beyond the CEA rules, general safety law expects employers to assess hazards and provide suitable PPE. The Occupational Safety, Health and Working Conditions Code, 2020, in force since 21 November 2025, now consolidates those duties for factories and construction sites.

Internationally, the pattern is similar. The US rule on foot protection, OSHA 1910.136, links protective footwear to electrical hazards that remain after other controls are in place, and US utility rules treat EH or dielectric footwear as supplementary protection against step and touch potentials.

In practice, the requirement on most Indian sites comes from three places: the CEA regulations for electrical work, the employer’s own risk assessment, and the client’s specification, since utilities, PSUs and large EPC contractors usually name EH or insulating footwear in their safety plans.

Jobs and tasks that call for them

Job or task Why the feet are exposed Footwear to specify
LV panel, DB and MCC maintenance, testing and fault-finding Accidental contact with live parts while equipment is energised for testing EH-rated safety shoes; insulating mat or Class 0 footwear for live work
Construction electricians: temporary power, cable pulling, DB installation Damaged cables, wrongly energised circuits, temporary installations EH-rated safety shoes
Cable jointing and termination Unexpected re-energisation, induced voltages, test voltages EH-rated safety shoes, with isolation and earthing
Substation operation and switching Step and touch potentials during a fault EH-rated safety shoes; insulating mats or dielectric overboots per utility practice
Overhead line ground crews Step potential around poles and earthing points during faults EH-rated boots, with temporary earthing
Solar PV installation and O&M DC strings stay live in daylight; damaged modules and cables EH-rated shoes, ideally with a DC rating, plus Class 0 gloves
Electric vehicle and battery workshops High-voltage DC battery systems Insulating footwear or mats as specified by the vehicle maker
Lift, HVAC and machine maintenance technicians Control panels and motor terminals near the work EH-rated safety shoes

Step and touch potentials are worth a word, because they surprise people. When a fault drives current into the ground, the voltage at the soil surface falls away with distance from the fault point. A person standing with their feet apart, or touching an earthed structure, can bridge a dangerous voltage difference without touching anything live. Good earthing design limits these voltages, which is why our guides to earthing system hardware for electrical contractors and copper earth rod sizing and installation sit alongside footwear in any substation safety plan.

When shock-resistant soles aren’t enough

Some situations call for more than EH-rated shoes:

  • Deliberate live working. Work on energised conductors needs class-rated insulating footwear or overboots to EN 50321-1, matched to the system voltage, together with class-rated gloves, insulating mats and the procedures that go with them. Our comparison of electrical gloves and industrial rubber gloves covers the glove classes, and our guide to safety helmet types by job role covers insulating helmets.
  • Wet or waterlogged areas. EH shoes lose protection when wet. Where electrical work has to happen in wet conditions, class-rated dielectric rubber boots are the usual choice.
  • DC systems. The EH test uses AC. For solar, battery and DC traction work, look for footwear with a stated DC rating if you are relying on it as part of your protection.

When You Should Not Wear Them

Explosive and flammable atmospheres

Petrol pumps, refineries, gas plants, paint booths, solvent stores, grain and flour handling, and many pharmaceutical and chemical plants need footwear that lets static charge drain away. Insulating soles do the opposite: they let charge build up on the body until it discharges as a spark, which is exactly what these areas are designed to prevent. Workers there should wear antistatic or conductive footwear, as the site’s hazardous-area classification specifies. For background on how static builds up and discharges, see the overview of electrostatic discharge.

Electronics and ESD-protected areas

Electronics assembly and repair areas use ESD footwear and flooring to protect components. Insulating soles defeat the system.

When both hazards exist

No shoe can be highly insulating and antistatic at the same time, because the two properties sit at opposite ends of the resistance scale. Where electrical work has to be done inside a hazardous area, sites usually rely on other controls: de-energising and locking out under a permit, using antistatic footwear for the atmosphere, and providing insulating mats and rated gloves for any unavoidable live testing. That decision belongs to the site’s electrical and safety engineers, so it should never be made by whoever is handing out shoes.

Four Common Misconceptions

“Any rubber-soled shoe is insulated.” Many rubber compounds contain carbon black and other fillers that can conduct, soles can hide nails or metal shanks, and none of it has been tested. Without a rating, a rubber sole is just a rubber sole.

“Gumboots are electrical boots.” Ordinary PVC or rubber gumboots are made for water and mud. Only dielectric boots that carry a class marking under EN 50321-1, or an equivalent tested rating, count as electrical protection.

“EH shoes make live work safe.” They are secondary protection, tested dry, for accidental contact. Live work needs isolation wherever possible, then class-rated gloves, insulating footwear or mats, insulated tools and a written procedure.

“If the floor has an insulating mat, footwear doesn’t matter.” A mat protects one fixed position, such as the area in front of a panel. As soon as the worker steps off it to fetch a tool or reach the next section, the shoes are all that remain.

The ISI Mark Gap

Here is a point many buyers miss. The 2024 edition of IS 15298 (Part 2), the Indian standard for safety footwear, removed the requirement for electrically insulating footwear. Insulation is now treated as a special risk covered by complementary standards such as EN 50321. Older catalogues may still show the symbol “I” from the earlier edition.

So the ISI mark on a safety shoe proves its toe cap, sole and other properties under IS 15298, but it says nothing about electrical insulation. If you need shock resistance, ask for it separately and ask for proof: an EH test report under ASTM F2413, or certification to EN 50321-1 with the class stated. Our comparison of steel-toe and composite-toe safety shoes explains why the toe cap material doesn’t settle this question either.

Five Questions Before You Issue a Pair

  1. Could this person touch, or stand near, something energised during their work? If not, ordinary safety footwear will do.
  2. Is the work done live, or only near live parts? Accidental exposure calls for EH-rated shoes. Deliberate live work calls for class-rated insulating footwear and the rest of a live-working kit.
  3. Is there a flammable atmosphere or an ESD-protected area? If so, antistatic or ESD footwear takes priority, and the electrical risk must be controlled in other ways.
  4. Will the feet be wet? If so, EH shoes alone are not enough. Consider dielectric rubber boots or change the method of work.
  5. Is the system AC or DC, and at what voltage? This decides whether a stated DC rating or a specific EN 50321 class is needed.

Three Workers, Three Different Answers

Running the five questions for three real roles shows how quickly the answer changes.

An electrician testing a live motor control centre in a cement plant. The work is near live parts and some fault-finding has to be done energised. The panel sits in a dry electrical room outside any hazardous area. The answer is EH-rated safety shoes, Class 0 electrical gloves with leather protectors, an insulating mat in front of the panel, and arc-rated face protection for the task, all under a written procedure for live testing.

An instrument technician working in a refinery tank farm. The area is classified as hazardous because of flammable vapours. Static discharge is the bigger footwear risk, so the answer is antistatic safety footwear, not EH. Any electrical work on instruments is done under a permit with isolation and gas testing, and the electrical risk is controlled through the permit rather than the shoes.

A solar O&M technician replacing damaged modules during the monsoon. The DC strings are live whenever the sun is up, and the ground between rows is often wet. EH-rated shoes with a stated DC rating suit dry days. On waterlogged days, dielectric rubber boots and Class 0 gloves rated for DC are safer, and isolating the string at the combiner box before touching anything is the first control. Our article on solar mounting structure hardware covers the racking these crews work around.

Same question, three different answers. The difference came from the atmosphere, the water and the type of current, which is why “electrical shoes” on its own is never a complete specification.

How to Check a Pair Before You Buy

On the shoe: an “EH” marking with ASTM F2413 for shock-resistant footwear, or the double triangle with a class number and EN 50321 for insulating footwear, along with the ISI mark and IS 15298 (Part 2) category for the safety properties. Many good electrical safety shoes carry both.

In the documents: a test report from an accredited laboratory that names the standard, the test voltage and the result, and matches the model you are buying.

In the construction: no nails or metal fasteners through the sole, a non-metallic shank, and an outsole free of cuts or embedded particles. A shoe described as “electrical” with none of these features is a shoe with a label, not a rating.

Our electric shock resistant shoes are supplied against your specification. Tell us the rating and standard you need, and we’ll quote and supply the test documentation with the order.

Care, Inspection and Retirement

The insulating value of a shoe can disappear long before the shoe wears out. Build these checks into the routine:

  • Inspect the soles weekly, and before electrical work, for cuts, cracks, punctures and embedded metal swarf, wire offcuts or stones.
  • Keep shoes dry. Dry them naturally overnight, away from heaters, and keep a second pair for wet seasons and long shifts.
  • Don’t modify them. Aftermarket insoles with metal parts, resoling and repairs can create conductive paths. ASTM F2413 states that modifying original components can void the marking.
  • Retire on wear. Replace shoes when the tread is worn smooth, the outsole is cut or punctured, the sole has separated, or metal parts are exposed.
  • Record class-rated footwear. EN 50321 boots and overboots have a marked space for the date of first use and each periodic inspection. Fill it in, and follow the manufacturer’s retest schedule.

These checks feed the PPE issue and replacement register described in our guide for safety officers.

Writing the Specification

Replace “electrical shoes, 50 pairs” with lines that name the standard and the rating:

  • ISI-marked safety footwear, IS 15298 (Part 2), class S1P or above, electrical hazard (EH) rated to ASTM F2413, sole free of metal fasteners, test report supplied with delivery: 50 pairs.
  • Electrically insulating boots to EN 50321-1, Class 0 (maximum 1,000 V AC / 1,500 V DC), with record space for inspection dates: 10 pairs.

Keep the electrical rating out of orders for people who work in hazardous areas, and specify antistatic footwear for them instead. Ankle height is a separate choice, covered in our article on picking the right ankle height for your site, and the wider PPE kit is set out in our construction site PPE selection guide.

Frequently Asked Questions

Are electric-shock-resistant shoes compulsory in India?

No law names them for every worker. The CEA Safety Regulations, 2023 require rubber safety footwear rated for the working voltage, along with other protective equipment, for people handling electric supply lines and apparatus, and employers must provide PPE that suits the hazards found in their risk assessment. Utilities and large contractors usually specify electrical-hazard footwear for electrical work in their safety plans.

What does an 18 kV rating on safety shoes mean?

It refers to the ASTM F2413 electrical hazard (EH) test, in which the shoe must withstand 18,000 V at 60 Hz for one minute with no more than 1.0 mA of leakage, under dry conditions. It is a secondary protection rating for accidental contact, not approval to work on equipment at 18 kV or any other voltage.

Are antistatic shoes the same as electric-shock-resistant shoes?

No. Antistatic shoes allow static charge to drain to the ground in a controlled way, and IS 15298 (Part 2) states that they do not protect against electric shock. Electric-shock-resistant shoes insulate the wearer from the ground. The two properties are opposites and suit different workplaces.

Do electric-shock-resistant shoes work when wet?

Their protection is reduced, often significantly. The EH rating is tested on dry footwear, and water, sweat, mud and worn or cut soles all reduce insulation. For electrical work in wet conditions, use class-rated dielectric rubber boots or change the method of work.

Can electricians wear steel-toe safety shoes?

Yes, if the shoe carries an electrical hazard rating. The cap sits sealed within the shoe’s structure, so protection depends on the sole and construction. Many EH-rated shoes have steel caps, though composite caps are popular for a fully metal-free build.

Does the ISI mark mean a safety shoe is electrically insulated?

No. The ISI mark shows that the shoe meets IS 15298 (Part 2), and that standard’s latest edition no longer covers electrically insulating footwear. Ask for a separate EH test report under ASTM F2413, or EN 50321-1 certification with the class stated.

When should EH shoes not be worn?

They should not be worn in explosive or flammable atmospheres, such as refineries, fuel stations, paint booths and solvent stores, or in ESD-protected electronics areas. Insulating soles let static build up on the body, so these areas require antistatic, conductive or ESD footwear.

Conclusion

Electric-shock-resistant shoes are required wherever electricity can reach a worker’s feet by accident: around panels, cables, substations, solar strings and machinery. They are a second line of defence, tested dry and weakened by water and wear, and they must give way to class-rated insulating footwear for live work and to antistatic footwear wherever the atmosphere can ignite. Write the rating into the order, ask for the test report, and inspect the soles as carefully as you would inspect a pair of electrical gloves.

The practical next step is a one-page list for each crew: the tasks, the voltages, whether the system is AC or DC, and any hazardous areas they enter. Our team can turn that list into a footwear specification and a quotation; the contact page is the quickest way to reach us.

3 thoughts on “Electric-Shock-Resistant Shoes: When Are They Required?”

Leave a Reply

Your email address will not be published. Required fields are marked *